Design of sintered zeolite evaporative cooling system
Keywords:
cooling efficiency, evaporative cooling system, relative humidity, sintered zeolite cooling pad, temperatureAbstract
An evaporative cooling system for fruit and vegetable was designed, fabricated, and evaluated in this study. The evaporative cooling system is made of plywood covered with steorofoam. The inside system is made of plywood with dimensions of 30 cm x 30 cm x 30 cm. The inside of the box is covered with steorofoam with a thickness of 2 cm on the front, sides and back. The cooling pad in this evaporative cooling system is sintered zeolite. Sintering zeolite is a new material used to optimize evaporative cooling systems. One suction fan to draw environmental air through the cooling pad and into the controlled room. There is a water reservoir used to collect cooling water and place a cooling water circulation pump. The pump lifts water from the reservoir then sprays the cooling pad through the pipe and then the water is stored back in the reservoir. As water drips through the cooling pad, the suction fan keeps the air moving and blowing through the cooling pad. When passing through the cooling pad, the evaporation process occurs, and the cooling effect takes place.
Downloads
References
Aked, J. (2002). Maintaining the postharvest quality of fruits and vegetables. Fruit and vegetable processing: improving quality, 119-149.
Ali, H. M. (2020). Recent advancements in PV cooling and efficiency enhancement integrating phase change materials based systems–A comprehensive review. Solar Energy, 197, 163-198. https://doi.org/10.1016/j.solener.2019.11.075
Amer, O., Boukhanouf, R., & Ibrahim, H. G. (2015). A review of evaporative cooling technologies. International journal of environmental science and development, 6(2), 111.
Aste, N., Del Pero, C., & Leonforte, F. (2017). Active refrigeration technologies for food preservation in humanitarian context–A review. Sustainable Energy Technologies and Assessments, 22, 150-160.
Atkin, O. K., & Tjoelker, M. G. (2003). Thermal acclimation and the dynamic response of plant respiration to temperature. Trends in plant science, 8(7), 343-351. https://doi.org/10.1016/S1360-1385(03)00136-5
Babaremu, K. O., Omodara, M. A., Fayomi, S. I., Okokpujie, I. P., & Oluwafemi, J. O. (2018). Design and optimization of an active evaporative cooling system. International Journal of Mechanical Engineering and Technology (IJMET), 9(10), 1051-1061.
Bodbodak, S., & Moshfeghifar, M. (2016). Advances in controlled atmosphere storage of fruits and vegetables. In Eco-friendly technology for postharvest produce quality (pp. 39-76). Academic Press.
Camargo, J. R. (2008). Evaporative cooling: water for thermal comfort. Ambiente e Agua-An Interdisciplinary Journal of Applied Science, 3(2), 51-61.
Cuce, P. M., & Riffat, S. (2016). A state of the art review of evaporative cooling systems for building applications. Renewable and Sustainable Energy Reviews, 54, 1240-1249. https://doi.org/10.1016/j.rser.2015.10.066
de’Gennaro, R., Cappelletti, P., Cerri, G., de’Gennaro, M., Dondi, M., Guarini, G., ... & Naimo, D. (2003). Influence of zeolites on the sintering and technological properties of porcelain stoneware tiles. Journal of the European Ceramic Society, 23(13), 2237-2245. https://doi.org/10.1016/S0955-2219(03)00086-4
Dincer, I. (2017). Refrigeration systems and applications. John Wiley & Sons.
Farfán, R. F. M., Zambrano, T. Y. M., Sosa, V. M. D., & Zambrano, R. A. M. (2021). Design and construction of a thermoelectric system for high performance computers. International Journal of Physical Sciences and Engineering, 5(2), 25–33. https://doi.org/10.29332/ijpse.v5n2.1359
Farfán, R. M., Zambrano, T. Y. M., León, G. T. R., Muentes, E. I. C., & Almendariz, F. E. L. (2022). Eco-design of an air conditioning system decrease in carbon footprint. International Journal of Physical Sciences and Engineering, 6(1), 39–49. https://doi.org/10.53730/ijpse.v6n1.4313
Handbook, A. S. H. R. A. E. (1996). HVAC systems and equipment (Vol. 39). chapter.
Hänel, G. (1976). The properties of atmospheric aerosol particles as functions of the relative humidity at thermodynamic equilibrium with the surrounding moist air. In Advances in geophysics (Vol. 19, pp. 73-188). Elsevier. https://doi.org/10.1016/S0065-2687(08)60142-9
Hatfield, J. L., & Prueger, J. H. (2015). Temperature extremes: Effect on plant growth and development. Weather and climate extremes, 10, 4-10. https://doi.org/10.1016/j.wace.2015.08.001
Ikechukwu-Edeh, C. E., Ndukwu, M. C., & Ahaneku, I. E. (2021). A review of common natural ventilation and evaporative cooling systems for Greenhouses and the Nigerian reality. Poljoprivredna tehnika, 46(3), 1-22.
Krishnakumar, T. (2002). Design of cold storage for fruits and vegetables. Tamil Nadu Agricultural University, 1-58.
lal Basediya, A., Samuel, D. V. K., & Beera, V. (2013). Electric Tempered Touch Screen Control Glass Panel Top Cover-abyea. org. Journal of Food Science and Technology, 50(3), 429.
Nikolajsen, K., Kiwi-Minsker, L., & Renken, A. (2006). Structured fixed-bed adsorber based on zeolite/sintered metal fibre for low concentration VOC removal. Chemical Engineering Research and Design, 84(7), 562-568. https://doi.org/10.1205/cherd.05220
Nkolisa, N., Magwaza, L. S., Workneh, T. S., & Chimphango, A. (2018). Evaluating evaporative cooling system as an energy-free and cost-effective method for postharvest storage of tomatoes (Solanum lycopersicum L.) for smallholder farmers. Scientia Horticulturae, 241, 131-143.
Rehman, S., & Mohandes, M. (2008). Artificial neural network estimation of global solar radiation using air temperature and relative humidity. Energy policy, 36(2), 571-576. https://doi.org/10.1016/j.enpol.2007.09.033
Riangvilaikul, B., & Kumar, S. (2010). Numerical study of a novel dew point evaporative cooling system. Energy and Buildings, 42(11), 2241-2250. https://doi.org/10.1016/j.enbuild.2010.07.020
Shashua-Bar, L., Pearlmutter, D., & Erell, E. (2009). The cooling efficiency of urban landscape strategies in a hot dry climate. Landscape and urban planning, 92(3-4), 179-186. https://doi.org/10.1016/j.landurbplan.2009.04.005
Tambunan, A. H., Rismawan, H. R., & Silalahi, I. (1999). Application of Evaporative Cooling System for Post Harvest Handling of Agricultural Products. Jurnal Keteknikan Pertanian, 13(1).
Vakiloroaya, V., Samali, B., Fakhar, A., & Pishghadam, K. (2014). A review of different strategies for HVAC energy saving. Energy conversion and management, 77, 738-754.
Zakari, M. D., Abubakar, Y. S., Muhammad, Y. B., Shanono, N. J., Nasidi, N. M., Abubakar, M. S., ... & Ahmad, R. K. (2016). Design and construction of an evaporative cooling system for the storage of fresh tomato. ARPN Journal of Engineering and Applied Sciences, 11(4), 2340-2348.
Published
How to Cite
Issue
Section
Copyright (c) 2022 International research journal of engineering, IT & scientific research
![Creative Commons License](http://i.creativecommons.org/l/by-nc-nd/4.0/88x31.png)
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Articles published in the International Research Journal of Engineering, IT & Scientific research (IRJEIS) are available under Creative Commons Attribution Non-Commercial No Derivatives Licence (CC BY-NC-ND 4.0). Authors retain copyright in their work and grant IRJEIS right of first publication under CC BY-NC-ND 4.0. Users have the right to read, download, copy, distribute, print, search, or link to the full texts of articles in this journal, and to use them for any other lawful purpose.
Articles published in IRJEIS can be copied, communicated and shared in their published form for non-commercial purposes provided full attribution is given to the author and the journal. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
This copyright notice applies to articles published in IRJEIS volumes 6 onwards. Please read about the copyright notices for previous volumes under Journal History.